What’s new. Peninsula Energy (ASX: PEN) has suspended production at its Lance uranium project in Wyoming after a cybersecurity incident hit the plant and wellfield operating and control systems. Its US subsidiary, Strata Energy, spotted the incident on the morning of Friday, Nov 20, US time. Peninsula shut operations down and isolated the affected systems (per Peninsula’s Nov 25 ASX update).
What’s confirmed.
- Peninsula says the incident so far appears confined to plant and wellfield operating and control systems. Corporate and admin systems in the US and Australia, including payroll and financial admin, are unaffected (per Peninsula’s ASX update).
- US authorities have been notified, and outside cyber, forensic and legal advisers are on it. Whether any data was hit is still under investigation.
- Restart date: none yet. Lance stays down until recovery and verification are done and Peninsula is satisfied the plant can safely run again.
- Peninsula can’t yet say if this hits its CY2027 guidance, which was 500k–600k lb U3O8 (per The Register). 2026 guidance was already withdrawn earlier this year after operating problems at Lance.
- Shares went into a trading halt on Nov 23, then a voluntary suspension until the earlier of Monday Nov 30 or an announcement on restarting Lance.
- Attacker: Undisclosed. Ransomware: not stated. Peninsula hasn’t said how they got in.
Why it matters. This is what an OT incident costs: not a data-breach notice, but a plant that stops. Lance was built for up to 2.0 Mlb of U3O8 a year and is licensed for 3.0 Mlb (per The Register), and every week it’s down is lost output for a small producer that was already behind plan. And “confined to OT, IT untouched” is the reverse of the usual pattern, where crews come in through IT and the plant gets shut as a precaution. If the control layer really was the only thing hit, the big open question is how someone reached the plant network without crossing IT first. In OT the usual suspects are remote vendor access, an exposed HMI or engineering workstation, and the links out to remote wellfield sites. Peninsula hasn’t said which, if any, applies here.
What we’d check this week if we ran OT security at a mine, utility or plant.
- List every route into the control network that doesn’t go through your IT/OT DMZ: vendor VPNs, remote-desktop tools on HMIs, cellular modems and radio links at remote sites. Wellfields and pump stations are where these tend to hide.
- Make remote access require MFA, be switched on only when needed, and get recorded. Kill any always-on vendor accounts and shared logins on engineering workstations.
- Check that you have offline, tested backups of PLC logic, HMI projects and historian configs. Restoring from a known-good copy is what sets your restart date, not the forensics report.
- Practice running in manual or degraded mode, and write down who signs off that a rebuilt control system is safe to put back in service. Peninsula’s “safe and controlled” restart is the slow part of any OT recovery.